NSTRUCTIONSI701 S. RIDGE AVENUETROY, OHIO 45374-0001937 332-3000www.hobartcorp.comFORM 35219 (Oct. 2007)MODEL 3813 & 3913 SLICERSMODELS3813 Manua
– 10 –Fig. 19Fig. 21RIDGE ON KNIFE HUB(PLASTIC COVERREMOVED)PIN @ 1 O’CLOCKHOLE @11 O’CLOCKKNIFE REMOVALTOOLPIN IN HOLE @11 O’CLOCKSLOTS AROUND 3 PINS
– 11 –To Reinstall the Knife . . .• Orient the RIDGE on the KNIFE HUB so it points to the PIN onthe RING GUARD at the 1 o'clock position (Fig. 24
– 12 –FORM 35219 (Oct. 2007)MAINTENANCE Unplug the machine power cord and turn the index knob fully clockwise toclose the gauge plate before doing any
– 2 –© HOBART CORPORATION 2007TABLE OF CONTENTSGENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Acces
– 3 –Installation, Operation and Care ofMODEL 3813 & 3913 SLICERSSAVE THESE INSTRUCTIONSGENERALThe model 3813 and 3913 slicers are equipped with a
– 4 –INSTALLATIONUNPACKINGImmediately after unpacking the slicer, check for possible shipping damage. If the slicer is found to bedamaged, save the pa
– 5 –ELECTRICAL This machine is provided with a three-prong grounding plug. The outlet to whichthis plug is connected must be properly grounded. If th
– 6 –TOP KNIFE COVERLATCH KNOB PRODUCT TRAYMEAT GRIP INDEXKNOBPRODUCT TRAYHANDLEMEAT GRIP SLOTGAUGEPLATEMEAT GRIPSLIDE RODPARK PINCARRIAGESLO
– 7 –SLICING — MODEL 3913• Close the GAUGE PLATE by turning the INDEX KNOB fully clockwise (Fig. 7).• Pull the PRODUCT TRAY (Fig. 7) all the way towar
– 8 –CLEANINGThis machine must be thoroughly cleaned and sanitized at least as often as required by local regulationor after being idle for an extende
– 9 –Clean completely around the RING GUARD by working amoistened, folded paper towel between the RING GUARD and theKNIFE (Fig. 15).Wash, rinse and sa