Hobart 125 EZ Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
OM-923 Page 9
SECTION 3 SPECIFICATIONS
3-1. Specifications
Rated Welding
Output
Maximum
Amperage
Maximum Open-
Circuit Voltage
DC
Amperes Input at
Rated Load Output
115 V, 60 Hz, Single-
Phase
KVA KW
Weight
W/ Gun
Overall
Dimensions
90 A @ 19 Volts DC,
20% Duty Cycle
63 A @ 21 Volts DC,
20% Duty Cycle*
125
29
20
15*
2.90
2.20*
2.50
1.77*
50 lb
(22.7 kg)
Length: 16-7/8 in
(429 mm)
Width: 9-7/8 in
(251 mm)
Height: 12-1/8 in
(308 mm)
Wire Type
Flux Cored Wire Feed Speed Range
Wi
re
T
ype
And Dia
.030 .035 in
(0.8 0.9 mm)
183 295 IPM (4.6 7.5 m/min) At No Load
112 236 IPM (2.8 6.0 m/min) Feeding Wire
* CSA Rating
3-2. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
Y Exceeding duty cycle can
damage unit or gun and void
warranty.
Overheating
0
15
A or V
OR
Reduce Duty Cycle
Minutes
duty1 4/95 210 517-A
20% duty cycle at 90 amps
2 Minutes Welding 8 Minutes Resting
1
4
20
40 60 100
2
68
10
20
40
60
80
100
200
135
10
Duty Cycle %
Output Amperes
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 43 44

Commentaires sur ces manuels

Pas de commentaire